Back to Top

1
Hi, Guest!

  LOKASI :  Kota Administrasi Jakarta Barat

BAGIKAN :   

Bagikan :
Kontak Kami  
PT. JE Indonesia ( Distributor & Service )

ABB B7-30-10-80 Mini Contactor 220-240V 40-450Hz GJL1311001R8100

Update Terakhir
:
18 / 10 / 2023
Min. Pembelian
:
1 Pcs

Harga

CALL
Bagikan
:
PT. JE Indonesia (Authorized Distributor & Stockist)
LTC Glodok
Ground Floor GF2 A23 No. 1
Jl. Hayam Wuruk 127
Jakarta 11180
Tel : 021-62311149 ( hunting)
Email : sales@ jakartaelectric.com

Detail ABB B7-30-10-80 Mini Contactor 220-240V 40-450Hz GJL1311001R8100

Perlengkapan Listrik Lainnya

Number of Poles:
3

Mini Contactor Type:
Mini Contactor

Rated Operational Voltage:
Auxiliary Circuit 690 V AC
Auxiliary Circuit 250 V DC
Main Circuit 690 V AC
Main Circuit 220 V DC

Rated Frequency (f):
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Main Circuit 60 Hz
Main Circuit 50 Hz
Main Circuit DC

Rated Impulse Withstand Voltage (Uimp):
Auxiliary Circuit 6 kV
Main Circuit 6 kV

Rated Insulation Voltage (Ui):
690 V
acc. to UL/CSA 600 V

Number of Main Contacts NC:
0

Number of Main Contacts NO:
3

Rated Operational Current AC-1 (Ie):
(220 / 240 V) 40 °C 20 A
(220 / 240 V) 55 °C 16 A
(380 / 440 V) 40 °C 20 A
(380 / 440 V) 55 °C 16 A
(690 V) 40 °C 6 A
(690 V) 55 °C 6 A

Rated Operational Power AC-3 (Pe):
(230 V) Three Phase 3 kW
(400 V) Three Phase 5.5 kW
(500 V) Three Phase 5.5 kW
(690 V) Three Phase, NO 3 kW

Rated Short-time Withstand Current Low Voltage (Icw):
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 96 A

Number of Auxiliary Contacts NC:
0

Number of Auxiliary Contacts NO:
1

Rated Operational Current AC-15 (Ie):
(24 V) 4 A
(120 V) 4 A
(500 V) 2 A
(220 / 240 V) 4 A
(380 / 400 V) 3 A

Rated Operational Current DC-13 (Ie):
(24 V) 2.5 A
(110 V) 0.7 A
(220 / 240 V) 0.4 A

Conventional Free-air Thermal Current (Ith):
Main Circuit 20 A

Rated Control Circuit Voltage (Uc):
220 ... 240 V AC

Coil Operating Limits:
(acc. to IEC 60947-4-1) for AC supply 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)

Degree of Protection:
Auxiliary Circuit Terminals IP20
Control Circuit Terminals IP20
Main Circuit Terminals IP20

Mechanical Durability:
10000000 cycle

Minimum Switching Capacity:
Auxiliary Circuit 17 V
Auxiliary Circuit 5 mA

Recommended Screw Driver:
M3
Pozidriv 1

Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715

Power Loss:
at Rated Operating Conditions AC-1 per Pole 1.4 W

Tampilkan Lebih Banyak