Detail ABB GJL1211001R8010 B6-30-01-80 220-240VAC Mini Contactor

Perlengkapan Listrik Lainnya

Number of Poles:
3

Mini Contactor Type:
Mini Contactor

Rated Operational Voltage:
Auxiliary Circuit 690 V AC
Auxiliary Circuit 250 V DC
Main Circuit 690 V AC
Main Circuit 220 V DC

Rated Frequency (f):
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Main Circuit 60 Hz
Main Circuit 50 Hz
Main Circuit DC

Rated Impulse Withstand Voltage (Uimp):
Auxiliary Circuit 6 kV
Main Circuit 6 kV

Rated Insulation Voltage (Ui):
690 V
acc. to UL/CSA 600 V

Number of Main Contacts NC:
0

Number of Main Contacts NO:
3

Rated Operational Current AC-1 (Ie):
(220 / 240 V) 40 °C 20 A
(220 / 240 V) 55 °C 16 A
(380 / 440 V) 40 °C 20 A
(380 / 440 V) 55 °C 16 A
(690 V) 40 °C 6 A
(690 V) 55 °C 6 A

Rated Operational Power AC-3 (Pe):
(230 V) Three Phase 2.2 kW
(400 V) Three Phase 4 kW
(500 V) Three Phase 4 kW
(690 V) Three Phase, NO 3 kW

Rated Short-time Withstand Current Low Voltage (Icw):
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 64 A

Number of Auxiliary Contacts NC:
1

Number of Auxiliary Contacts NO:
0

Rated Operational Current AC-15 (Ie):
(24 V) 4 A
(120 V) 4 A
(500 V) 2 A
(220 / 240 V) 4 A
(380 / 400 V) 3 A

Rated Operational Current DC-13 (Ie):
(24 V) 2.5 A
(110 V) 0.7 A
(220 / 240 V) 0.4 A

Conventional Free-air Thermal Current (Ith):
Main Circuit 20 A

Rated Control Circuit Voltage (Uc):
220 ... 240 V AC

Coil Operating Limits:
(acc. to IEC 60947-4-1) for AC supply 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)

Degree of Protection:
Auxiliary Circuit Terminals IP20
Control Circuit Terminals IP20
Main Circuit Terminals IP20

Mechanical Durability:
10000000 cycle

Minimum Switching Capacity:
Auxiliary Circuit 17 V
Auxiliary Circuit 5 mA

Maximum Electrical Switching Frequency:
(AC-1) 300 cycles per hour
(AC-15) 600 cycles per hour
(AC-3) 600 cycles per hour
(DC-1) 600 cycles per hour
(DC-13) 600 cycles per hour
(DC-3) 600 cycles per hour

Connecting Capacity Main Circuit:
Flexible with Ferrule 1/2x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm²
Flexible 1/2x 1 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²

Connecting Capacity Auxiliary Circuit:
Flexible with Ferrule 1/2x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm²
Flexible 1/2x 1 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²

Connecting Capacity Control Circuit:
Flexible with Ferrule 1/2x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm²
Flexible 1/2x 1 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²

Wire Stripping Length:
Auxiliary Circuit 9 mm
Main Circuit 9 mm

Tightening Torque:
Auxiliary Circuit 0.8 ... 1.1 N·m
Control Circuit 0.8 ... 1.1 N·m
Main Circuit 0.8 ... 1.1 N·m

Recommended Screw Driver:
M3
Pozidriv 1

Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715

Power Loss:
at Rated Operating Conditions AC-1 per Pole 1 W

Standards:
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 60947-5-1
UL 60947-1
UL 60947-4-1