Back to Top

1
Hi, Guest!

  LOKASI :  Kota Administrasi Jakarta Barat

BAGIKAN :   

Bagikan :
Kontak Kami  
PT. JE Indonesia ( Distributor & Service )

ABB KONTAKTOR MINI 1NC 24VAC K6-40E-01 GJH1211001R0401

Update Terakhir
:
20 / 10 / 2023
Min. Pembelian
:
1 Pcs

Harga

CALL
Bagikan
:
PT. JE Indonesia (Authorized Distributor & Stockist)
LTC Glodok
Ground Floor GF2 A23 No. 1
Jl. Hayam Wuruk 127
Jakarta 11180
Tel : 021-62311149 ( hunting)
Email : sales@ jakartaelectric.com

Detail ABB KONTAKTOR MINI 1NC 24VAC K6-40E-01 GJH1211001R0401

Perlengkapan Listrik Lainnya

Coil Consumption:
Average Holding Value 50 Hz 3.5 V·A
Average Pull-in Value 50 Hz 3.5 V·A

Coil Operating Limits:
(acc. to IEC 60947-5-1) for AC supply 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)

Connecting Capacity Auxiliary Circuit:
Flexible with Ferrule 1/2x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm²
Flexible 1/2x 1 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²

Connecting Capacity Control Circuit:
Flexible with Ferrule 1/2x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm²
Flexible 1/2x 1 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²

Maximum Electrical Switching Frequency:
(AC-15) 600 cycles per hour
(DC-13) 600 cycles per hour

Mechanical Durability:
10000000 cycle

Mini Contactor Type:
Mini Contactor Relay

Minimum Mounting Distance:
Other Device Same Type, Horizontal 0 mm

Minimum Switching Capacity:
17 V
5 mA

Mounting Position:
1 ... 6

Mounting Type:
DIN-Rail
Screw

Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715

Number of Auxiliary Contacts NC:
0

Number of Auxiliary Contacts NO:
4

Number of Main Contacts NC:
0

Number of Main Contacts NO:
0

Number of Poles:
4

Power Loss:
at Rated Operating Conditions per Pole 0.32 W

Rated Control Circuit Voltage (Uc):
24 V AC

Rated Frequency (f):
Auxiliary Circuit 50 Hz
Auxiliary Circuit 60 Hz
Auxiliary Circuit DC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Main Circuit 60 Hz
Main Circuit 50 Hz
Main Circuit DC

Rated Impulse Withstand Voltage (Uimp):
Auxiliary Circuit 6 kV

Rated Insulation Voltage (Ui):
690 V
acc. to UL/CSA 600 V

Rated Operational Current AC-15 (Ie):
(24 V) 4 A
(120 V) 4 A
(240 V) 4 A
(400 V) 3 A
(500 V) 2 A

Rated Operational Current DC-13 (Ie):
(24 V) 2.5 A
(110 V) 0.7 A
(220 / 240 V) 0.4 A

Rated Operational Voltage:
Auxiliary Circuit 690 V AC
Auxiliary Circuit 250 V DC

Recommended Screw Driver:
M3
Pozidriv 1

Short-Circuit Protective Devices:
gG Type Fuses 6 A

Standards:
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 60947-5-1
UL 60947-1
UL 60947-4-1

Terminal Type:
Screw Terminals

Tightening Torque:
Auxiliary Circuit 0.8 ... 1.1 N·m
Control Circuit 0.8 ... 1.1 N·m
Main Circuit 0.8 ... 1.1 N·m

Wire Stripping Length:
Auxiliary Circuit 9 mm

Tampilkan Lebih Banyak