Back to Top

1
Hi, Guest!

  LOKASI :  Kota Administrasi Jakarta Barat

BAGIKAN :   

Bagikan :
Kontak Kami  
PT. JE Indonesia ( Distributor & Service )

ABB KONTAKTOR MODEL MCB 4POLE 4NO 220V ESB40-40N-06 1SAE341111R0640

Update Terakhir
:
20 / 10 / 2023
Min. Pembelian
:
1 Pcs

Harga

CALL
Bagikan
:
PT. JE Indonesia (Authorized Distributor & Stockist)
LTC Glodok
Ground Floor GF2 A23 No. 1
Jl. Hayam Wuruk 127
Jakarta 11180
Tel : 021-62311149 ( hunting)
Email : sales@ jakartaelectric.com

Detail ABB KONTAKTOR MODEL MCB 4POLE 4NO 220V ESB40-40N-06 1SAE341111R0640

Perlengkapan Listrik Lainnya

Rated Operational Voltage:
Main Circuit 220 V DC
Main Circuit 400 V AC

Rated Control Circuit Voltage (Uc):
230 V

Rated Frequency (f):
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC

Rated Operational Current AC-1 (Ie):
(NO) 40 A

Rated Operational Current AC-3 (Ie):
(230 V) Single Phase, NO 22 A
(400 V) Three Phase, NO 22 A

Rated Operational Power AC-1 (Pe):
(230 V) Single Phase, NO 9.2 kW
(400 V) Three Phase, NO 27.7 kW

Rated Operational Power AC-3 (Pe):
(230 V) Single Phase, NO 3.7 kW
(400 V) Three Phase, NO 11 kW

Rated Operational Current AC-7a (Ie):
(NO) 40 A

Rated Operational Power AC-7a (Pe):
(230 V) Single Phase, NO 9.2 kW
(400 V) Three Phase, NO 27.7 kW

Rated Operational Current AC-7b (Ie):
(230 V) Single Phase, NO 22 A
(400 V) Three Phase, NO 22 A

Rated Operational Power AC-7b (Pe):
(230 V) Single Phase, NO 3.7 kW
(400 V) Three Phase, NO 11 kW

Recommended Screw Driver:
Control Circuit Pozidriv 1
Main Circuit Pozidriv 2

Rated Impulse Withstand Voltage (Uimp):
6 kV

Rated Insulation Voltage (Ui):
500 V

Connecting Capacity Main Circuit:
Flexible with Ferrule 1x 1.5 ... 16 mm²
Flexible with Ferrule 2x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 16 mm²
Flexible with Insulated Ferrule 2x 1.5 ... 10 mm²
Flexible 1x 1.5 ... 16 mm²
Flexible 2x 1.5 ... 10 mm²
Rigid 1x 1.5 ... 25 mm²
Rigid 2x 1.5 ... 10 mm²

Connecting Capacity Control Circuit:
Flexible with Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²

Tightening Torque:
Control Circuit 0.9 N·m
Main Circuit 2.5 N·m

Wire Stripping Length:
Control Circuit 7 mm
Main Circuit 13 mm

Degree of Protection:
IP20

Electrical Durability:
AC-1 (NO) 150000 cycle
AC-3 (NO) 100000 cycle
AC-7a (NO) 150000 cycle
AC-7b (NO) 100000 cycle

Mechanical Durability:
1000000 cycle

Number of Poles:
4

Number of Auxiliary Contacts NC:
0

Number of Auxiliary Contacts NO:
0

Number of Main Contacts NC:
0

Number of Main Contacts NO:
4

Width in Number of Modular Spacings:
3

Pollution Degree:
3

Standards:
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1